Hardware Installation
TheRBT8500WirelessSwitchcanbemountedinast andard
19inch(48.26cm)equipmentrack,oronatabletop.Eachswitchis
shippedwithtwobracketsforrackmountingandfouradhesive
rubberfeetfortabletopmounting.Themountingbracketssupport
frontmountingonly.Thebracketkitallowsyou
toinstallthe
RBT8500WirelessSwitchintomostfourpostrackandcabinet
systems.TheonlytoolrequiredisaPhillipsscrewdriver.
Cabling Information
Cable Requirements
Toavoidinstallationproblems,usethepropercables.
Serial Console Cable
TheserialconsoleporthasafemaleDB9connectorandsupportsthe
EIA232Dsignalingstandard.Youneeda standardDB9maleto
DB9femalePCmodemcable.
Supported Interfaces and Cable Types
Table 1liststheinterfacetypessupportedbytheswitch,andthe
cable
typerequiredforeachtypeofinterface.Table 2provides
specificationsforthe10/100Managementport.
Connecting the Cables
ConnectyourI/OcablesasshowninFigure 1,andpressthepower
button.RefertotheEnterasysRoamAboutRBT8500WirelessSwitch
InstallationGuideforadditionalsetupinstructions.
TheSerialNumber,MACAddress,andotheridentifyinginformation
arelocatedontherearpanel.
Caution: Ensure that you wear the ESD (Electrical Static
Discharge) strap during the installation.
Caution: The Gigabit Ethernet fiber-optic interfaces use Class 1
lasers. To reduce the risk of eye injury, do not stare into the
interface or otherwise direct the laser beam into your eye.
Table 1 Mini-GBIC Input/Output Specifications
Enterasys Part Wavelength Cable Port/Ethernet
MGBIC-02 1550 nm EML Copper RJ45/1000BASE-T
MGBIC-08 1550 nm EML Single mode LC/1000BASE-ELX
MGBIC-LC01 850 nm DFB Multimode LC/1000BASE-SX
MGBIC-LC03 1310 nm VCSEL Multimode LC/1000BASE-SX
MGBIC-LC09 1310 nm VCSEL Single/Multimode LC/1000BASE-LX
MGBIC-MT01 850 nm VCSEL Multimode MT-RJ/1000BASE-SX
Note: Refer to Appendix A of the RBT-8500 Wireless Switch
Installation Guide, for additional Mini-GBIC specifications.
Table 2 Management Port Specifications
10/100 Management Port Cable Port Type/Ethernet
Used for out-of-band management only Copper RJ45/10/100BASE-T
Figure 1 Front I/O Ports and Features
StatusLEDsaredescribedinTable 3.
Initial Configuration
OnceyourRBT8500isphysicallyinstalled,youcanconfigureit
quicklyusingthequickstartcommand,whichrunsaninteractive
scriptthatpromptsyouforrequiredinformationandliststhedefault,
ifapplicable.
RefertotheEnterasysRoamAboutRBT8500WirelessSwitchInstallation
Guideforinformationaboutotherinitializationoptions.
You
musthavethefollowinginformationtocompletethe
configuration:
•IPaddress
•NetworkSubnetMasks
A Power Supply 1 inlet F Power supply 1 LED
B Power Supply 2 inlet G Power supply 2 LED
C 10/100 Management port H Management LED
D Serial console port I Mini-GBIC slot
E Gigabit link LEDs J Mini-GBIC slot
Table 3 Status LEDs
LED Color Action Description
Management Green Bright to Faded The switch is operating
normally.
Green Blinking The switch is booting.
Amber Blinking Rapidly The switch was unable to
boot completely.
Power Supply
Status
Green Solid DC power output is ON.
Amber Solid A power fault has
occurred.
OFF LED is not lit AC power is OFF.
Fiber Link
Activity
Green Solid The 1000-Mbps fiber link
is operational.
Green Blinking The 1000-Mbps fiber link
is receiving/sending
traffic.
Copper Link
Activity
Green Solid The 1000-Mbps copper
link is operational.
Green Blinking The 1000-Mbps copper
link is receiving/sending
traffic.
RBT-8500
1Console 2
Mgmt (3)
A
H
I
J
E
DC
F
B
G
Performthefollowingstepstorunthequickstartcommand:
1. Usethenullmodemcable toattachaPCtotheRoamAbout
WirelessSwitch’sserialconsoleport.Donotattempttoconnecta
monitor,keyboard,ormousetotheswitch.
2. PressEnterthreetimes.
3. Atthecommandprompt,entertheenablecommand.
4. Enterquickstart
.
Thecommandasksyouaseriesofquestions.Youcantype?for
morehelp.Toquit,pressCtrl+C.
TheSerialNumber,MACAddress,andotheridentifying
informationarelocatedontherearpanel.
Oneofthequestionsthescriptasksisthecountrycode.Foralistof
validcountry codes,refertoeithertheEnterasysRoamAboutMobility
SystemSoftwareConfigurationGuideortheEnterasysRoamAbout
MobilitySystemSoftwareCommandLineInterfaceReference .
Anotherquestionthescriptasksis,“Doyouwishtoconfigure
wireless?”Ifyouanswery,thescriptgoesontoaskyouforSSID
anduserinformation,andforunencryptedandencryptedSSIDs.If
youanswern,thescriptgenerateskeypairsforSSHandthe
administrativeusersyouentered,generatesaselfsigned
administrativecertificate,andthenends.
5. Optionally,enableTelnet.
RBT8500#setiptelnetserverenable
6. Savetheconfigurationchanges.
RBT8500#
saveconfig
7. Verifytheconfigurationchanges.
RBT8500#showconfig
Getting Help
ForadditionalsupportrelatedtotheRBT8500WirelessSwitch,or
thisdocument,contactEnterasysNetworksusingoneofthefollowing
methods:
World Wide Web www.enterasys.com/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
For the Enterasys Networks Support toll-free
number in your country:
www.enterasys.com/support/
Internet mail [email protected]
To expedite your message, type [ROAMABOUT]
in the subject field of your message.
The latest image
and release notes
www.enterasys.com/services/support/downloads/
software
More
documentation
www.enterasys.com/support/manuals/
To send comments concerning this document to the Technical
Publications Department: [email protected]
Please include the document Part Number in your email message.
Notice
EnterasysNetworksanditslicensorsreservetherighttomakechangesin
specificationsandotherinformationcontainedin thisdocumentanditswebsite
withoutpriornotice.ThereadershouldinallcasesconsultEnterasysNetworksto
determinewhetheranysuchchangeshavebeenmade.
Thehardware,firmware,orsoftwaredescribed
inthismanualissubjecttochange
withoutnotice.
INNOEVENTSHALLEnterasysNetworksANDITSLICENSORSBELIABLEFOR
ANYINCIDENTAL,INDIRECT,SPECIAL,ORCONSEQUENTIALDAMAGES
WHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISING
OUTOFORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHE
INFORMATIONCONTAINEDIN
THEM,EVENIFEnterasysNetworksANDITS
LICENSORSHAVEBEENADVISEDOF,KNOWN,ORSHOULDHAVEKNOWN,
THEPOSSIBILITYOFSUCHDAMAGES.
EnterasysNetworks,Inc.
50MinutemanRoad
Andover,MA01810
©2008EnterasysNetworks,Inc.Allrightsreserved.
PartNumber: 903437301 January2008
Enterasys,EnterasysNetworks,ENTERASYSNETSIGHT,ENTERASYSRoamAbout,
andanylogosassociated
therewith,aretrademarksorregisteredtrademarksof
EnterasysNetworks,Inc.intheUnitedStatesandothercountries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregistered
trademarksoftheirrespectivecompanies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothe
followingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)
thisdevicemustacceptanyinterferencereceived,includinginterferencethatmay
causeundesiredoperation.
NOTE: Thisequipmenthasbeentestedandfoundtocomply
withthelimitsfora
classAdigitaldevice,pursuanttoPart15oftheFCCrules.Theselimitsaredesigned
toprovidereasonableprotectionagainstharmfulinterferencewhentheequ ipmentis
operatedinacommercialenvironment.Thisequipmentuses,generates,andcan
radiateradiofrequencyenergyandifnot
installedinaccordancewiththeoperator’s
manual,maycauseharmfulinterferencetoradiocommunications.Operationofthis
equipmentinaresidentialareaislikelytocauseinterferenceinwhichcasetheuser
willberequiredtocorrecttheinterferenceathisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhich
arenotexpressly
approvedbythepartyresponsibleforcompliancecouldvoidtheuser’sauthorityto
operatetheequipment.
Industry Canada Notice
ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissions
fromdigitalapparatussetoutintheRadioInterferenceRegulationsoftheCanadian
DepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruitsradioélectriquesdépassantles
limitesapplicablesauxappareilsnumériquesdelaclassAprescrites
dansle
Règlementsurlebrouillageradioélectriqueédictéparleministèredes
CommunicationsduCanada.
Class A ITE Notice
WARNING:ThisisaClassAproduct.Inadomesticenvironmentthisproductmay
causeradiointerferenceinwhichcasetheusermayberequiredtotakeadequate
measures.
Clase A. Aviso de ITE
ADVERTENCIA:EsteesunproductodeClaseA.Enunambientedomésticoeste
productopuedecausarinterferenciaderadioencuyocasopuedeserrequerido
tomarmedidasadecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS:DiesesProduktzähltzurKlasseA(Industriebereich).In
WohnbereichenkanneshierdurchzuFunkstörungenkommen,dahersollten
angemesseneVorkehrungenzumSchutzgetroffenwerden.
17x8.5incheswithbleed
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Getting Help

Hardware InstallationTheRBT‐8500WirelessSwitchcanbemountedinast andard19‐inch(48.26‐cm)equipmentrack,oronatabletop.Eachswitchissh

Page 2 - Enterasys RoamAbout

Product SafetyThisproductcomplieswiththefollowing:UL 60950,CSAC22.2No. 60950,2006/95/EC,EN 60950,IEC 60950,EN60825,21CFR1040.10.Segur

Commentaires sur ces manuels

Pas de commentaire