Enterasys APS-3000 Spécifications Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 500
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
Enterasys Wireless Controller Software CLI Reference Guide 3-5
Parameters
None
Examples
EWC.enterasys.com:availability# fast_failover
3.2.5 link_timeout
Usethelink_timeoutcommandtospecifythetimeperiodinwhichthelinkfailurebetweenthe
WirelessAPsandtheprimarycontrollerin‘availability’modewouldbedetected.
Syntax
link_timeout <seconds>
Parameters
Examples
Thefollowingexamplesetsthetimeforlinkfailuredetectionto10seconds
EWC.enterasys.com:availability# link_timeout 10
3.2.6 sync-config
Usethesyncconfigcommandtoenableordisablesynchronizationoftheconfigurationelements.
Syntax
sync-config enable | disable
Parameters
Examples
Thefollowingexampleenablesthesynchronization oftheconfigurationelements.
EWC.enterasys.com:availability# sync-config enable
<seconds>
Specifiestimeperiodinsecondsbeforelinkfailureisdetected
Note: The time for the link failure is in seconds. You can specify the time for link failure detection
between the range of 2 to 30 seconds.
enable Enablesynchronizationoftheconfigurationelements.
disable Disablesynchronizationoftheconfigurationelements.