Enterasys Enterasys SecureStack B2 B2G124-24 Guide d'installation

Naviguer en ligne ou télécharger Guide d'installation pour Commutateurs de réseau Enterasys Enterasys SecureStack B2 B2G124-24. Enterasys Enterasys SecureStack B2 B2G124-24 Installation guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 78
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
7.5x9-inch cover with bleed on 4 sides
SecureStack B2
Gigabit and Fast Ethernet Switches
Hardware Installation Guide
B2G124-24
B2G124-48
B2H124-48
P/N 9034099-02
Vue de la page 0
1 2 3 4 5 6 ... 77 78

Résumé du contenu

Page 1 - SecureStack B2

7.5x9-inch cover with bleed on 4 sidesSecureStack B2Gigabit and Fast Ethernet SwitchesHardware Installation GuideB2G124-24B2G124-48B2H124-48P/N 903409

Page 2

viii 8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcriticalvaluetoEnterasysand,

Page 3

ixContentsAbout This GuideWho Should Use This Guide ...

Page 4

xConnecting AC and RPS-SYS Power ...3-15AC Power ...

Page 5 - BSMI EMC Statement — Taiwan

xiFigures1-1 B2G124-24 Stackable Switch ...1-31-2 B2G124-

Page 7 - Declaration of Conformity

SecureStack B2 Installation Guide xiiiAbout This GuideThisguideprovidesanoverview,installationandtroubleshootinginstructions,andspecificati

Page 8 - Firmware License Agreement

How to Use This Guidexiv About This GuideHow to Use This GuideReadthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandgainan

Page 9

Conventions Used in This GuideSecureStack B2 Installation Guide xvConventions Used in This Guide Thefollowingconventionsareusedinthisguide:Not

Page 10

Conventions Used in This Guidexvi About This Guide

Page 11 - Contents

SecureStack B2 Installation Guide 1-11IntroductionThischapterintroducestheB2G124‐24, B2G124‐48,and B2H124‐48stackableswitches.Important Notic

Page 13

Overview1-2 IntroductionOverviewTheB2G124‐24,B2G124‐48,andB2H124‐48arestackableFastEthernetandGigabitEthernetswitches,whichcanbeadapte

Page 14

OverviewSecureStack B2 Installation Guide 1-3Figure 1-1 B2G124-24 Stackable SwitchFigure 1-2 B2G124-48 Stackable Switch1 DB9 RS232 Console port con

Page 15 - About This Guide

Overview1-4 IntroductionB2H124-48TheB2H124‐48 (Figure 1‐3)hasthefollowingfrontandrearpanelportconnections:•RJ45ports(10/100Mbpscopperpo

Page 16 - Related Documents

ConnectivitySecureStack B2 Installation Guide 1-5High-Speed Stack ConnectionsTheswitcheshaverear‐panelconnectorsforhigh‐speedconnectionsina

Page 17

Connectivity1-6 IntroductionTable 1-1 Description of Mini-GBICsMini-GBIC SpecificationMGBIC-LC01 Provides one 1000BASE-SX compliant LC fiber-optic mul

Page 18

ManagementSecureStack B2 Installation Guide 1-7ManagementManagementofthemodulecanbeeitherin‐bandorout‐of‐band.In‐bandremotemanagementis

Page 19 - Introduction

Getting Help1-8 IntroductionGetting HelpForadditionalsupportrelatedtotheswitchesorthisdocument,contactEnterasys Networksusingoneofthef

Page 20 - Overview

Enterasys SecureStack B2 Installation Guide 2-12Network RequirementsBeforeinstallingthedevice,reviewtherequirementsandspecificationsinthis

Page 21

100BASE-TX Network2-2 Network Requirements100BASE-TX NetworkWhenconnectinga100BASE‐TXsegmenttooneofthefixedports(1 through24onB2G124‐24,

Page 22 - B2H124-48

SecureStack B2 Installation Guide 3-13Hardware InstallationThischapterprovidesinstructionstoinstalltheB2G124‐24,B2G124‐48,andB2H124‐48.Unl

Page 23 - Connectivity

iNoticeEnterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentanditswebsitewitho

Page 24 - Mini-GBIC Specification

Considerations Prior to Installation3-2 Hardware InstallationConsiderations Prior to InstallationWheninstallingtheswitch,notethefollowing:•Befor

Page 25 - LANVIEW Diagnostic LEDs

Installing Optional Mini-GBICsSecureStack B2 Installation Guide 3-3Installing Optional Mini-GBICs ThissectiondescribeshowtoinstallMini‐GBICsin

Page 26 - Getting Help

Installing Optional Mini-GBICs3-4 Hardware InstallationInstallationToinstallaMini‐GBICthathasanMT‐RJconnector,refertoFigure 3‐1,orforaM

Page 27 - Network Requirements

Installing Optional Mini-GBICsSecureStack B2 Installation Guide 3-5Figure 3-2 Mini-GBIC with LC ConnectorRemoving the Mini-GBICToremoveaMini‐GBIC

Page 28 - 1000BASE-T Network

Installing the Switch on a Flat Surface3-6 Hardware Installation3. LocatethereleasetabunderthefrontendoftheMini‐GBIC.ForthetypeofMini‐G

Page 29 - Hardware Installation

Installing the Switch on a Flat SurfaceSecureStack B2 Installation Guide 3-7Figure 3-3 Chassis Bottom, Rubber Feet Placement4. Removetheprotective

Page 30 - Unpacking the Switch

Installing the Switch on a Flat Surface3-8 Hardware InstallationGuidelines for Flat Surface InstallationLocatetheswitchwithin152cm(5ft)ofits

Page 31 - Preparation

Rack Mounting the SwitchSecureStack B2 Installation Guide 3-9Rack Mounting the Switch Toinstalltheswitchina19‐inchrack,youneed:•Tworackmou

Page 32 - Installation

Connecting High-Speed Stacking Cables3-10 Hardware InstallationFigure 3-5 Attaching the Rackmount Brackets2. Withthemountingbracketsattached,pos

Page 33 - Removing the Mini-GBIC

Connecting High-Speed Stacking CablesSecureStack B2 Installation Guide 3-11Thehigh‐speedstackingcablesareoptionalitemsandmustbeorderedsepa

Page 34 - Installing the Rubber Feet

ii Regulatory Compliance InformationFederal Communications Commission (FCC) NoticeThisdevicecomplieswithPart15oftheFCCrules.Operationissub

Page 35

Configuring Switches in a Stack3-12 Hardware InstallationFigure 3-7 High-Speed Stacking Cable ConnectionsAfterconnectingthecablestothestacking

Page 36 - referto

Configuring Switches in a StackSecureStack B2 Installation Guide 3-13Onceinstalledinastack,theswitchesbehaveandperformasasingleswitch.A

Page 37 - Rack Mounting the Switch

Configuring Switches in a Stack3-14 Hardware InstallationRecommended Procedures for New and Existing StacksInstalling a New Stackable System of Up to

Page 38 - 3-10 Hardware Installation

Connecting AC and RPS-SYS PowerSecureStack B2 Installation Guide 3-15Adding a New Switch to an Existing StackUsethefollowingproceduretoinstalla

Page 39

Connecting AC and RPS-SYS Power3-16 Hardware InstallationFigure 3-8 Switch Rear View3. ObservethatthepowerCPULED(notshown),locatedonthefro

Page 40 - 3 STACK UP connector

Connecting AC and RPS-SYS PowerSecureStack B2 Installation Guide 3-17C2RPS-SYS Redundant Power SystemIfyouareinstallinganoptionalredundantpowe

Page 41

Connecting to Console Port for Local Management3-18 Hardware InstallationConnecting to Console Port for Local ManagementThissectiondescribeshowto

Page 42 - Important

Connecting to Console Port for Local ManagementSecureStack B2 Installation Guide 3-19Figure 3-9 DB9 Male Console Port Pinout AssignmentsConnecting t

Page 43 - AC Power

Connecting to Console Port for Local Management3-20 Hardware InstallationFigure 3-10 Connecting an IBM PC or CompatibleConnecting to a VT Series Term

Page 44 - 3-16 Hardware Installation

Connecting to Console Port for Local ManagementSecureStack B2 Installation Guide 3-21Figure 3-11 Connecting a VT Series TerminalConnecting to a Mode

Page 45 - Stack Initialization Overview

iiiElectromagnetic Compatibility (EMC)Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN61000‐3‐2,

Page 46 - What Is Needed

Connecting to the Network3-22 Hardware InstallationFigure 3-12 Connecting to a ModemConnecting to the NetworkThefollowingprocedurescoverthecable

Page 47

Connecting to the NetworkSecureStack B2 Installation Guide 3-232. ConnectthetwistedpairsegmenttotheswitchbyinsertingtheRJ45connectoront

Page 48 - 3-20 Hardware Installation

Connecting to the Network3-24 Hardware InstallationFigure 3-14 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TXFigure 3-15 Four-Wire Straigh

Page 49 - Connecting to a Modem

Connecting to the NetworkSecureStack B2 Installation Guide 3-25Figure 3-16 Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TXFigure 3-17

Page 50 - Connecting to the Network

Connecting to the Network3-26 Hardware InstallationConnecting Fiber-Optic Cables to MT-RJ PortsThissectioncontainstheproceduresforconnectinga1

Page 51 - 2 Port 8

Connecting to the NetworkSecureStack B2 Installation Guide 3-27.2. InserttheMT‐RJcableconnectorintothe MT‐RJconnectoruntilitclicksintopl

Page 52 - 3-24 Hardware Installation

Connecting to the Network3-28 Hardware Installationb. Ifthereareseparatefiber‐opticconnectionsontheotherdevice,checkthecrossoveroftheca

Page 53 - 1000BASE-TX

Connecting to the NetworkSecureStack B2 Installation Guide 3-29ToconnectanLCcableconnectortoafixedLCconnectorofaMini‐GBIC,refertoFigu

Page 54 - 3-26 Hardware Installation

Connecting to the Network3-30 Hardware InstallationFigure 3-19 Cable Connection to LC Fiber-Optic Connectors3. Plugtheotherendofthecableintot

Page 55

Completing the InstallationSecureStack B2 Installation Guide 3-31Completing the InstallationAfterinstallingtheswitchandmakingtheconnectionsto

Page 56 - 3-28 Hardware Installation

iv Safety InformationClass 1 Laser TransceiversThe single mode interface modules use Class 1 laser transceivers. Read the following safety information

Page 57

Completing the Installation3-32 Hardware Installation

Page 58 - 3-30 Hardware Installation

Enterasys SecureStack B2 Installation Guide 4-14TroubleshootingThischapterprovidesinformationconcerningthefollowing:Thisdevicecontainsabatt

Page 59 - Completing the Installation

Using LANVIEW4-2 TroubleshootingUsing LANVIEWTheseswitchessupporttheEnterasys Networksbuilt‐inLANVIEWLEDvisualdiagnosticandstatusmonitorin

Page 60 - 3-32 Hardware Installation

Using LANVIEWEnterasys SecureStack B2 Installation Guide 4-3Figure 4-2 LANVIEW LEDs of B2H124-48Table 4‐1describestheLEDindicationsandprovides

Page 61 - Troubleshooting

Using LANVIEW4-4 TroubleshootingTable 4-1 LANVIEW LEDsLED Color State Recommended ActionCPU Off Power disconnected. If the LED remains off after conne

Page 62 - Using LANVIEW

Using LANVIEWEnterasys SecureStack B2 Installation Guide 4-5UP Off No valid connection to switch stackdown connector.1. Make sure the switch connecte

Page 63

Troubleshooting Checklist4-6 TroubleshootingTroubleshooting ChecklistIfthedeviceisnotworkingproperly,refertoTable 4‐2forachecklistofprob

Page 64 - Table 4-1 LANVIEW LEDs

Troubleshooting ChecklistEnterasys SecureStack B2 Installation Guide 4-7Cannot navigate beyond startup screen.Improper Community Names Tab le .Refer

Page 65

Using the Reset Switch4-8 TroubleshootingUsing the Reset SwitchIfyouforgettheswitchloginpassword,usetheResetswitchasdescribedinthefollo

Page 66 - Troubleshooting Checklist

Enterasys SecureStack B2 Installation Guide A-1ASpecificationsThisappendixprovidesinformationaboutthefollowing:Enterasys Networksreservesthe

Page 67

vDeclaration of ConformityApplicationofCouncilDirective(s): 89/336/EEC73/23/EECManufacturer’sName: Enterasys Networks, Inc.Manufacturer’sAddress:

Page 68 - STACK DOWN

Switch SpecificationsA-2 SpecificationsB2G124-48RJ45ports 1 through 48 Forty-eight, 10BASE-T/100BASE-TX/1000BASE-T compliant ports with auto-sensing

Page 69 - Specifications

Mini-GBIC Input/Output SpecificationsEnterasys SecureStack B2 Installation Guide A-3Mini-GBIC Input/Output SpecificationsTheMini‐GigabitEthernetCa

Page 70 - A-2 Specifications

Gigabit Ethernet SpecificationsA-4 SpecificationsGigabit Ethernet SpecificationsThefollowingspecificationsfortheMini‐GBICsshowninTable A‐3thr

Page 71 - 441.87 Btu/hr

Gigabit Ethernet SpecificationsEnterasys SecureStack B2 Installation Guide A-5MGBIC-LC09 Specifications (1000BASE-LX)Table A-6 MGBIC-LC03 Operating R

Page 72

Gigabit Ethernet SpecificationsA-6 SpecificationsMGBIC-08 Specifications (1000BASE-ELX) MGBIC-02 Specifications (1000BASE-T)Table A-9 MGBIC-08 Optical

Page 73

Console Port Pinout AssignmentsEnterasys SecureStack B2 Installation Guide A-7Console Port Pinout AssignmentsTheConsoleportisaDB9serialcommuni

Page 74

Regulatory ComplianceA-8 Specifications

Page 75 - Regulatory Compliance

Index-1IndexNumerics1000BASE-SX/LX network connectionsrequirements for 2-21000BASE-Trequirements for 2-2100BASE-TXrequirements 2-210BASE-Tconnection 3

Page 76 - A-8 Specifications

Index-2PPinout assignmentsconsole port A-7UTP 4-wire crossover cable 3-24UTP 4-wire straight-through cable 3-24UTP 8-wire crossover cable 3-25UTP 8-wi

Page 77

vi Enterasys Networks, Inc.Firmware License AgreementBEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,CAREFULLY READ THIS LICENSE AGREEMENT.Thisdocum

Page 78

vii3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourtsoftheCommonwealthofMassa

Commentaires sur ces manuels

Pas de commentaire