Enterasys SecureStack A2 A2H123-24 Guide d'installation Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
Connecting Stacking Cables
3-8 Hardware Installation
Figure 35showsanexampleofafourhighstackconnectedinaclosedloop
configuration.AllSTACKDOWNandSTACKUPconnectorsareusedintheinstallation.
ThestackingcableconnectionsarefromtheSTACKDOWNconnectorofoneswitchto
theSTACKUPconnectorofthenextswitchup
inthestack.Astackingcableconnection
fromtheSTACKDOWNconnectoroftheswitchatthetopofthestacktotheSTACKUP
connectoratthebottomofthestackclosestheloop.Inadaisychainconfiguration,one
cableconnectionisnotmade.
Figure 3-5 Stacking Cable Connections
Afterconnectingthecables
tothestackingports,proceedtoConfiguringSwitchesina
Stackonpage 39forinstructions.
1 Category 5 or better UTP cable 4 STACK UP connector at top of stack
2 STACK UP connector 5 STACK DOWN connector at bottom of
stack
3 STACK DOWN connector
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 63 64

Commentaires sur ces manuels

Pas de commentaire