Passwords Screen
Accessing Local Management 3-29
3.8 PASSWORDS SCREEN
When to Use
To provide additional security by using login passwords associated to access policy. This screen
allows the use of passwords to provide three levels of Local Management access (super-user,
read-write and read-only) via serial console or telnet connection. This screen is also used to disable
the function of hardware switch 8 to prevent the clearing of the login passwords.
How to Access
Use the arrow keys to highlight the PASSWORDS menu item on the Security Menu screen and
press ENTER. The Module Login Passwords screen, Figure 3-9, displays.
Screen Example
Figure 3-9 Module Login Passwords Screen
3650_23
EXIT RETURNSAVE
Password Access Policy
******** read-only
******** read-write
******** super-user
SWITCH 8 [ENABLED]
Restrict NVRAM Passwords from upload/download [DISABLED]