Enterasys Enterasys Gold Distributed Forwarding Engine 4G4282-49 Guide d'installation Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
DFE-Gold Module Shutdown Procedure
4-8 Troubleshooting
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESET switch,youhave60
secondsfromthetimetheCPUstartsalternatelyflashingamber/offuntilthedevice
automaticallyrestarts.
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
ToresetaDFEGoldmodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
RemovinganyDFEGoldmodulefromthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetoremovea module fromthechassisis
afterthe
completionofashutdownandthemanagementLEDisalternatelyflashingamber/off.
Note: The only safe time to remove a DFE-Gold module from the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
Caution: This method of shutting down a DFE module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted,
resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del
módulo en funcionamiento, lo que podría resultar pérdidas de frames.
Vue de la page 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 89 90

Commentaires sur ces manuels

Pas de commentaire