Enterasys Enterasys SecureStack B2 B2G124-24 Spécifications Page 138

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 488
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 137
Port Configuration Command Set
Reviewing Port Status
3-6 SecureStack B2 Configuration Guide
3.3.1.2 show port status
Use this command to display operating and admin status, speed, duplex mode and port type for one
or more ports on the device.
show port status [port-string]
Syntax Description
Command Defaults
If port-string is not specified, status information for all ports will be displayed.
Command Mode
Read-Only.
Example
This example shows how to display status information for ge.3.1 through 4:
Table 3-1 provides an explanation of the command output.
port-string (Optional) Displays status for specific port(s). For a
detailed description of possible port-string values, refer to
Section 3.1.1.
B2(rw)->show port status ge.3.1-4
Port Alias Oper Admin Speed Duplex Type
(truncated) Status Status
------------ -------------- ------- ------- -------- ------- -------------
ge.3.14 up up 1.0G full 10 t
Table 3-1 show port status Output Details
Output What It Displays...
Port Port designation. For a detailed description of possible
port-string values, refer to Section 3.1.1.
Oper Status Operating status (up or down).
Vue de la page 137