Enterasys Enterasys SecureStack B2 B2G124-24 Spécifications Page 319

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 488
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 318
VLAN Configuration Command Set
Configuring the VLAN Egress List
SecureStack B2 Configuration Guide 6-23
6.3.4.2 set vlan forbidden
Use this command to prevent one or more ports from participating in a VLAN. This setting instructs
the device to ignore dynamic requests (either through GVRP or dynamic egress) for the port to join
the VLAN.
set vlan forbidden vlan-id port-string
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Example
This example shows you how to set fe.1.3 to forbidden for VLAN 6:
vlan-id Specifies the VLAN for which to set forbidden port(s).
port-string Specifies the port(s) to set as forbidden for the specified
vlan-id.
B2(rw)->set vlan forbidden 6 fe.1.3
Vue de la page 318
1 2 ... 314 315 316 317 318 319 320 321 322 323 324 ... 487 488

Commentaires sur ces manuels

Pas de commentaire