Security Configuration Command Set
Configuring MAC Locking
SecureStack B2 Configuration Guide 11-35
11.3.4 Configuring MAC Locking
Purpose
To review, disable, enable and configure MAC locking. This locks a MAC address to one or more
ports, preventing connection of unauthorized devices via the port(s). When source MAC addresses
are received on specified ports, the switch discards all subsequent frames not containing the
configured source addresses. The only frames forwarded on a “locked” port are those with the
“locked” MAC address(es) for that port.
Commands
The commands needed to configure MAC locking are listed below and described in the associated
section as shown:
show maclock (Section 11.3.4.1)
show maclock stations (Section 11.3.4.2)
set maclock enable (Section 11.3.4.3)
set maclock disable (Section 11.3.4.4)
set maclock firstarrival (Section 11.3.4.5)
clear maclock firstarrival (Section 11.3.4.6)
set maclock trap (Section 11.3.4.7)