Connecting to the Network
SecureStack A2 Installation Guide 3-29
Connecting UTP Cables to RJ45 Ports
ThefixedRJ45frontpanel10/100MbpsportsandtheRJ45MiniGBIC(MGBIC02)
Gigabitportsarebothinternallycrossed.Whenconnectingaworkstationtotheseports,
useastraightthroughcable.Whenconnectingnetworkingdevicestotheseports,suchas
abridge,repeater,orrouter,itisnotnecessary
touseacrossovercable.
Toconnecttwistedpairsegmentstotheswitch,refertoFigure316andproceedas
follows:
1. Ensurethatthedevicetobeconnectedattheotherendofthesegmentis
poweredON.
2. ConnectthetwistedpairsegmenttotheswitchbyinsertingtheRJ45connectoronthe
twistedpairsegmentintothedesiredRJ45port(forexample,Port7).
Figure 3-16 Connecting a UTP Cable Segment to RJ45 Port
Note: All RJ45 ports support Category 5 Unshielded Twisted Pair (UTP) cabling with an
impedance between 85 and 111 ohms. Category 3 cable may be used if the connection is
going to be used only for 10 Mbps.
1 RJ45 cable connector 3 Front panel port Link/Activity LED
2 RJ45 front panel port