Enterasys Enterasys SecureStack B2 B2G124-24 Spécifications Page 117

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 600
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 116
set port inlinepower
SecureStack B2 Configuration Guide 5-5
B2(su)->show port inlinepower fe.2.1
Port Type Admin Oper Priority Class Power(W)
---- ---- ----- ---- -------- ----- --------
fe.2.1 wireless auto searching low 0 15.4
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePoEonportfe.3.1withcriticalpriority:
B2(su)->set port inlinepower fe.3.1 admin auto priority critical
portstring Specifiestheport(s)onwhichtoconfigurePoE.
adminoff|auto SetsthePoEadministrativestatetooff(disabled)orauto(on).
prioritycritical|
high|low
Setstheport(s)priorityfor thePoEallocationalgorithmtocritical
(highest),highorlow.
typetype Specifiesastringdescribingthetype
ofdeviceconnectedtoaport.
Vue de la page 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 599 600

Commentaires sur ces manuels

Pas de commentaire