clear maclock
SecureStack B2 Configuration Guide 19-55
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
ConfiguringaportforMAClockingrequiresgloballyenablingitontheswitchfirstusingtheset
maclockenablecommandasdescribedinsetmaclockenableonpage 1953.
StaticMAClockingauseronmultipleportsisnotsupported.
StaticallyMAC lockedaddresseswilldisplayintheshowmac
output(asdescribedonpage1520)
asaddresstype“otherandwillnotremovethemonlinkdown.
Example
ThisexampleshowshowtocreateaMAClockingassociationbetweenMACaddress0e03efd8
4455andport
ge.3.2:
B2(rw)->set maclock 0e-03-ef-d8-44-55 ge.3.2 create
clear maclock
UsethiscommandtoremoveastaticMACaddresstoportlockingentry.
Syntax
clear maclock mac-address port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
create EstablishesaMAClockingassociationbetweenthespecifiedMAC
addressandport.CreateautomaticallyenablesMAC lockingbetweenthe
specifiedMACaddressandport.
enable|disable EnablesordisablesMAClockingbetweenthespecifiedMACaddressand
port.
macaddress SpecifiestheMACaddressthatwillberemovedfromthelistofstatic
MACsallowedtocommunicateontheport.
portstring SpecifiestheportonwhichtocleartheMACaddress.Foradetailed
descriptionofpossibleportstringvalues,refertoPortStringSyntaxUsed
intheCLI
onpage 72.