clear system temperature
3-18 Basic Configuration
Usage
Ontheplatformsthatsupportthisfeature,temperaturesensorsarelocatedinseveraldifferent
locationswithinthedevice.Thresholdcalibrationshavebeencalculatedseparatelyforeach
platform.Thethermalovertempthresholdisthehighwatermarkthat,whenreached,triggersan
alerttowarnthesy stemadministratorthatthedeviceis
operatingathightemperatures.
Thevaluessetwiththiscommandcanbeviewedwiththeshowsystemcommand.
RefertotheReleaseNoteforyourplatformtodetermineifthisfeatureissupportedonyour
platform.
Example
ThefollowingexampleenablessendingSNMPtrapsandsetstheovertempthresholdto60%.
B2(su)->set system temperature trap enable overtemp-threshold 60
clear system temperature
Usethiscommandtoresetsystemhightemperatureparameterstotheirdefaultvalues,onthe
platformsthatsupportthisfeature.
Syntax
clear system temperature
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
Thiscommandresetsallthehightemperatureparameterstotheirdefaultvalues:
•Syslogalertsaredisabledbydefault.
•Trapalertsaredisabledbydefault.
•Overtempthresholdis100%bydefault.
Example
Thisexampleresetsallhightemperatureparameterstotheirdefaults.
B2(su)->clear system temperature