set spantree spanguardtrapenable
9-30 Spanning Tree Configuration
set spantree spanguardtrapenable
UsethiscommandtoenableordisablethesendingofanSNMPtrapmessagewhenSpanGuard
haslockedaport.
Syntax
set spantree spanguardtrapenable {disable | enable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtodisabletheSpanGuardtrapfunction:
B2(su)->set spantree spanguardtrapenable disable
clear spantree spanguardtrapenable
UsethiscommandtoresettheSpanningTreeSpanGuardtrapfunctionbacktothedefaultstateof
enabled.
Syntax
clear spantree spanguardtrapenable
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoresettheSpanGuardtrapfunctiontoenabled:
B2(rw)->clear spantree spanguardtrapenable
disable|enable DisablesorenablessendingSpanGuardtraps.Bydefault,sendingtraps
isenabled.