show summertime
3-20 Basic Configuration
show summertime
Usethiscommandtodisplaydaylightsavingstimesettings.
Syntax
show summertime
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaydaylightsavingstimesettings:
B2(su)->show summertime
Summertime is disabled and set to ''
Start : SUN APR 04 02:00:00 2004
End : SUN OCT 31 02:00:00 2004
Offset: 60 minutes (1 hours 0 minutes)
Recurring: yes, starting at 2:00 of the first Sunday of April and ending at 2:00
of the last Sunday of October
set summertime
Usethiscommandtoenableordisablethedaylightsavingstime function.
Syntax
set summertime {enable | disable} [zone]
Parameters
Defaults
Ifazonenameisnotspecified,nonewillbeapplied.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtoenabledaylightsavingstimefunction:
B2(su)->set summertime enable
enable|disable Enablesordisablesthedaylightsavingstimefunction.
zone (Optional)Appliesanametothedaylightsavingstimesettings.