show snmp engineid
8-4 SNMP Configuration
Commands
show snmp engineid
UsethiscommandtodisplaytheSNMPlocalengineID.ThisistheSNMPv3engine’s
administrativelyuniqueidentifier.
Syntax
show snmp engineid
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaySNMPengineproperties:
B2(su)->show snmp engineid
EngineId: 80:00:15:f8:03:00:e0:63:9d:b5:87
Engine Boots = 12
Engine Time = 162181
Max Msg Size = 2048
Table 814providesanexplanationofthecommandoutput.
For information about... Refer to page...
show snmp engineid 8-4
show snmp counters 8-5
Table 8-14 show snmp engineid Output Details
Output Field What It Displays...
EngineId String identifying the SNMP agent on the device.
Engine Boots Number of times the SNMP engine has been started or reinitialized.
Engine Time Time in seconds since last reboot.
Max Msg Size Maximum accepted length, in bytes, of SNMP frame.